LungFit® PH uses patented Plasma Pulse Technology® to generate inhaled nitric oxide (iNO) from ambient air in the room, eliminating the need for iNO source supplies like cylinders or cassettes.
Harnessing the Power of Nitric Oxide
Generate Continuous, Unlimited iNO at the Point of Care.

Quick & Simple Setup

Confident iNO Delivery

Enhanced Efficiency
Initiate iNO Therapy Quickly & Simply
-
- Start iNO therapy in 1 minute with quick, simple steps
-
- Power on, make 3 familiar connections, and set a dose
-
- Start iNO therapy in 1 minute with quick, simple steps
-
- Unburden your respiratory therapy (RT) department and enable more time to focus on patient care
-
- No concerns about watching a supply source, such as cylinders or chemical-filled cassettes, because you never run out of room air
-
- Predictable 12-hour filter life regardless of dose or gas flow
-
- Automated alerts notify staff when filter change is needed
- Palm-sized, lightweight design for easy handling
- Can coordinate filter changes with vent checks for efficiency
-
- Predictable 12-hour filter life regardless of dose or gas flow

Confidently Deliver the Set Dose
-
- NO delivery of 0.1–80 ppm, gas flow of 0.5–100 L/min
-
- Main and backup generators are the size of a D battery and use the energy of a 60W bulb to produce NO from room air
-
- Main, backup, and bagging modes with the flexibility to deliver iNO continuously through both the main injector line and bagging system
-
- Proven dual-channel independent delivery and monitoring methods for confidence in delivering a set dose
- Precise real-time measurement of ventilator gas flow to maintain accurate and stable iNO delivery
- Proven dual-channel independent delivery and monitoring methods for confidence in delivering a set dose
-
- Up to 4 hours backup battery life
-
- Empower staff with limited iNO experience to be confident delivering nitric oxide therapy

Enhance Efficiency by Eliminating need for iNO Source Supplies
-
- Eliminate burden of inventory management, storage space, and safety risk for iNO supplies
-
- No special storage requirements
-
- No hazardous materials or heavy, bulky cylinders
-
- No storage space needed for full and depleted cylinders
-
- All other components are disposable patient accessories
-
- No reusable components requiring sterilization
Exclusive Plasma Pulse Technology®
The first and only FDA approved system that generates iNO from room air.1
Here’s how it works:

Compact and energy-efficient: Generators the size of a D battery use minimal power to reliably produce iNO from room air
Micro-pulses of energy produce a precise amount of NO to deliver the set dose
NO2 Smart Filter removes NO2 from the internal circuit to reduce patient and staff exposure

Explore your cost savings and find out how you can get annual budget certainty at a competitive price
All-inclusive, contracts including device, accessories, service and support
Custom-built proposals based on device needs and volume of usage

Important Safety Information
IMPORTANT SAFETY INFORMATION
-
- The nitric oxide from the LungFit PH is contraindicated in neonates dependent on right-to-left shunting of blood.
- Methemoglobin levels increase with the dose of nitric oxide; it can take 8 hours or more before steady-state methemoglobin levels are attained. Monitor methemoglobin and adjust the dose of nitric oxide to optimize oxygenation.
INDICATIONS FOR USE
The nitric oxide from the LungFit PH System is indicated to improve oxygenation and reduce the need for extracorporeal membrane oxygenation in term and near-term (>34 weeks gestation) neonates with hypoxic respiratory failure associated with clinical or echocardiographic evidence of pulmonary hypertension in conjunction with ventilatory support and other appropriate agents. Refer to the full Prescribing Information within the LungFit PH System Operator’s Manual before use.
- CAUTION
-
- To maintain the LungFit PH batteries in a charged state, keep the system plugged in between uses.
-
- Rx Only
-
- Consult the LungFit PH System Operator’s Manual for complete information. For technical support, call 1-855-586-4359.
-
DEVICE WARNINGS
-
- Persons using the LungFit PH System should be trained and experienced in its use before performing procedures described in this manual to assure effective administration of nitric oxide and to avoid injury to the patient or to others resulting from inhalation of excess nitric oxide, nitrogen dioxide, or other reaction products.
- Abrupt discontinuation of nitric oxide may lead to worsening oxygenation and increasing pulmonary artery pressure, ie., Rebound Pulmonary Hypertension Syndrome. Signs and symptoms of Rebound Pulmonary Hypertension Syndrome include hypoxemia, systemic hypotension, bradycardia, and decreased cardiac output. If Rebound Pulmonary Hypertension occurs, reinstate nitric oxide therapy immediately.
- A non-expired NO2 Filter must be properly installed at all times for the LungFit PH System to function. Always have at least 1 spare NO2 Filter available.
- Do not make unauthorized changes to the device as it can result in harm to the patient.